ECOFLEX Undertile Heating Cable Kit

ECOFLEX Undertile Heating Cable Kit

Product Code: Ecoflex

Available Options

£0.00 inc VAT
-+
free shipping
50 year
24 support

ECOFLEX cables provide an underfloor heating solution in your kitchen, bathroom or conservatory. The cables can be fitted on top of existing wooden or concrete floors that are sound and suitably prepared.

ECOFLEX cables are ideal for smaller installations or in rooms with an irregular layout. The flexibility of the loose cabling system makes it possible to heat the maximum floor area including hard to reach areas.


Features

  • Small diameter cable
  • Available as a separate loose cable or a complete solution in a convenient package
  • ECOFLEX can be installed under many floor coverings including ceramic tiles, natural stone and slate
  • Twin conductor ultra flexible cable simplifies installation with only a single “cold tail” connection
  • Two extremely tough, durable insulation layers which minimises the risk of damage during the installation process and ensures prolonged cable life
  • Approved to IEC 60800

Technical Detail

  • Maximum Power Loading - 10W/lin metre
  • Diameter - 3.3-4.3mm for cable drums and less than 3mm for cable kits
  • 230V supply
  • Twin conductor cable
  • 1 x 3m cold tail connection lead

Product Options


LOOSE CABLE OPTION
loose cable

ECOFLEX underfloor heating cables are available as a loose cable only option for installation by professional installers. Each cable is packaged on a convenient cardboard cable drum and heat sealed for protection. Minimum packaging provides an economical and environmentally friendly solution for the professional installer. Thermostats and fixing and installation accessories are available as optional extras.


CABLE KIT OPTION
ECOFLEX Undertile Heating Cable Kit

ECOFLEX cable kits come complete with: heating cable, floor primer, adhesive fixing tape and comprehensive fitting instructions. Required accessories such as a thermostat and floor insulation are available separately.


Floor Construction

construction
SUSPENDED FLOORS

When fitting ECOFLEX undefloor heating cable to a timber sub-floor it is essential that standard precautions to stabilise the floor are taken to prevent floor movement. All chipboard & timber floorboards must be covered with either ECOMAX insulated tile backer board or 18mm Plywood.

TOP LAYER - Tile / Stone floor
SECOND LAYER - Tile Adhesive / Self leveling compound
THIRD LAYER - ECOFLEX Cable
FOURTH LAYER - ECOMAX Thermal Insulation
FIFTH LAYER - Suspended Timber Floor


CONCRETE FLOORS

For optimal performance it is recommended before laying ECOFLEX cable, a layer of ECOMAX insulated tile backer board is fitted. This will minimise heat losses and ensure quicker heat-up times for the floor. ECOFLEX can be laid directly onto an uninsulated floor, however this will increase running costs & heat-up times.

TOP LAYER - Tile / Stone floor
SECOND LAYER - Tile Adhesive / Self leveling compound
THIRD LAYER - ECOFLEX Cable
FOURTH LAYER - ECOMAX Thermal Insulation
FIFTH LAYER - Concrete Floor